HELIX PEC

Screens for wall loss straight through coating and insulation.

A HELIX pulsed eddy current probe strapped to an in-service line outdoors

A handheld pulsed eddy current instrument that screens wall response through coatings and insulation. No surface prep, no bare metal, no couplant, and no shutdown: the line stays in service while it is read.

What the probe measures.

The probe measures the decay of a transient eddy-current response and reports it as relative apparent wall.

The pulsed eddy current field over a steel wall: the coil's field lines, then the eddy currents decaying in the metal

The pulsed eddy current field over a steel wall, and the eddy currents decaying in it.

Wall-response screening

System
HELIX PEC-Rev1 (deployed units PEC-1a, PEC-1b)
Measurement
Decay constant τ (ms) of the transient eddy-current response, reported as relative apparent-wall response
Probe
Concentric coil, 90 mm excitation, 40 mm read
Footprint
~90 mm. Each reading is a footprint average
Material
Ferromagnetic metal. Comparisons valid within consistent material and geometry
Reference framework
ISO 20669:2017 (reference only)

Limits

PEC is footprint-averaged: it responds to ferromagnetic deposits as if they were wall, and does not resolve isolated pitting. PEC values are relative, based on τ, rather than absolute thickness, unless a material reference exists.